5-7 Section 5: Module Configuration
Moseley SL9003Q 602-12016 Revision G
5.2.1. AES/EBU and SPDIF
Switch S81 configures the digital audio input (Encoder) or output (Decoder) for the
AES/EBU “professional” standard (3 wire XLR balanced) or SPDIF “consumer” standard
(2 wire unbalanced). The AES/EBU setting is the factory default. The following wiring
shown in Figures 5-5 through 5-8 should be followed for the proper level and phasing:
XLR (female)
Ground
+
(HOT)
-
Figure 5-5 AES/EBU-XLR Encoder Connection
XLR (female)
Ground
+
(HOT)
-
Figure 5-6 SPDIF-XLR Encoder Connection
XLR (male)
Ground
+
(HOT)
-
Figure 5-7 AES/EBU-XLR Decoder Connection
XLR (male)
Ground
+
(HOT)
-
Figure 5-8 SPDIF-XLR Decoder Connection