Broadcast Tools SS 4.1 III Spécifications Page 9

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 13
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 8
e-mail:
voice:
360.854.9559
fax:
866.783.1742
9
SS 4.1 Plus Installation and Operation Manual
INSTALLATION
Status
The status signals are supplied through the “Remote” control connector TB-3 as
individual open collectors. The open collectors may be used to provide status to a
remote control point to indicate which source is selected. The status open collector
(OCx) output for the selected channel will go low providing a return for an LED
indicator, TTL/CMOS logic or relay. External pull-up resistors may be required in
some installations.
Connecting the remote control, PIP / Trigger Inputs and OC’s / SS Relay
Most front panel functions of the SS 4.1 Plus may be remote controlled via the plug-
gable euroblock screw terminals located on the rear panel. The SS 4.1 Plus accepts
momentary contact closures (sustained, if break before make); open collector or
TTL/CMOS input logic levels. Connections to the remote control and/or PIP (trig-
ger) inputs are made on the TB-4. The following information is a comparison chart
to be used when connecting external devices.
Rear Panel Connectors
TB 1 —> TB 2 EVEN Inputs Top Row
Input x – Left Input x + Left Gnd Input x – Right Input x + Right
Input x – Left Input x + Left Gnd Input x – Right Input x + Right
ODD Inputs Bottom Row
TB 3 Audio Output Top Row
Output - Left Output + Left Gnd Output - Right Output + Right
Open Collector 1 Open Collector 2 Gnd Open Collector 3 Open Collector 4
Open Collector Outputs Bottom Row
TB 4 Remote input / Triggers Top Row
PIP 4 PIP 5 PIP 6 PIP 7 PIP 8 Gnd
SS Relay N.O. SS Relay CM PIP 1 PIP 2 PIP 3 Gnd
SS Relay & Remote Inputs / Triggers Bottom Row
Note: Remote control cross-reference information is on the next page.
Vue de la page 8
1 2 3 4 5 6 7 8 9 10 11 12 13

Commentaires sur ces manuels

Pas de commentaire