WVRC-8 Installation and Operation Manual
INSTALLATION
Dial-Up Programming
Follow the steps below to configure the WVRC-8 for dial-up operation.
Installing factory defaults.
Remove power from the unit. Hold down the “PGM” button down while reinstalling the
power plug. The “PGM” button must be held down for a few seconds after the power is
restored. When the PGM button is released, the PGM LED will blink twice to show that
the defaults were loaded
.
CAUTION! If you reinstall factory defaults, the standard factory recorded voice prompts
are not reloaded. The user MUST re-record the voice prompts.
NOTE: The dial-up programming may be accomplished locally using the RS-232 serial
port or via the web using Telnet.